Simple Wireless WiFi Bridge

The SunSpot WiFi Simple Wireless Bridge kit makes connecting field devices simple and you don’t have to be a wireless network specialist to use it. Connect your trackers to the Internet effortlessly and get all the benefits of remote monitoring.

SunSpotSimple

Click for enlarged view

There are no antennas to contend with because the antenna is housed in the radio itself, simply point it towards the opposite radios. Distances can conservatively be up to 1000 feet (longer distances available) with one or more Clients. The SunSpot WiFi is industrial and designed for outdoor use and can be mounted to a 1/2in. conduit to 2.5 in. pipe or use the window mounting kit. There are other bracketing types available.

Proven in Arizona’s 120F summers and Montana’s -20C winters without a single failure, SunSpot is low cost without any reduction in performance. The kit comes with the radios preconfigured and a rugged outdoor carrier class Ethernet cable.wiringPOE_LAN

The Access Point connects to your Local Area Network and is set up to receive an IP address automatically. If you have a restricted network typical in large companies which requires an IT department intervention, we provide instructions to IT Managers for MAC Address resolution and security information.

 

Contact us for large scale WiFi networks for solar fields.

Dual Axis Controller

TRACKER500

 

 

 

 

 

 

 

PERFORMANCE SPECIFICATIONS

  •  Industrial powerPC (32 bit data bus)
  • Operating system embedded Linux
  • Dynamic memory (RAM) 32 Mbytes – 32bit, 0 wait states
  • Program memory (Flash) 32 Mbytes
  • Retained memory (RAM) 512K (battery-backed)
  • Data logging (OPTIONAL)
  • Custom programming available

 ETHERNET PORT

  • 10/100BaseTx (auto-detecting)
  • RJ45 connection (auto-crossover)
  • Protocols TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP, DNP3 Slave

 SERIAL PORT

  • RS485 port A screws (485+, 485-, GND) (2-wire half-duplex)
  • RS232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR,DSR, GND)
  • Protocols (master & slave) SIXNET & Modbus RTU/ASCII;
  • Flow control hardware, software, RTS-party (for radios and RS485)

 DISCRETE INPUTS

  • 12 channels (sinking or sourcing)
  • Guaranteed ON voltage 9 VDC
  • Maximum voltage 30 VDC
  • Guaranteed OFF voltage & current 5.0 VDC & 1.5 mA DC
  • Input resistance 10K Ohms
  • Input current @ 24 VDC 3 mA
  • Filtered ON/OFF delay 25 mS (20 Hz max. counting)
  • Fast ON/OFF delay 4 mS (100 Hz max. counting)
  • Count rate (channels 1 – 8) (10 KHz on channel 1)

DISCRETE OUTPUTS

  • 4 channels (10-30 VDC)
  • Maximum output per channel 1 Amp
  • Maximum output per module 4 Amps
  • Max. OFF state leakage 0.05 mA
  • Minimum load 1 mA
  • Inrush current 5 Amps (100 mS surge)
  • Typical ON resistance 0.3 Ohms
  • Typical ON voltage (@1A) 0.3 VDC

ANALOG INPUTS

  • 8 channels (4-20 mA, 0-2VDC, 0-5VDC, 0-10VDC)
  • A/D resolution 16 bits (0.003%)
  • Full scale accuracy +/-0.1% (@20°C)
  • Span and offset temp. coef. +/-50 ppm per °C
  • Input impedance 100 Ohm
  • Current protection Self-resetting fuses
  • DMRR (differential mode rejection) 66 dB at 50/60 Hz

ANALOG OUTPUTS

  • up to 2 channels (4-20 mA, 0-20mA 0-10VDC with Resistor)
  • D/A resolution 16 bits (less than 1?A)
  • Full scale accuracy (@20°C) +/- 0.02%
  • Span and offset temp. coef. +/- 50 ppm per °C typical
  • Max. output settling time 5 mS (to .05%)
  • Load resistance range (@ +24 VDC supply) 0-750 Ohms
  • Short circuit protection current limiting

 ENVIRONMENTAL

  • DIN rail or fl at panel mount
  • Input power 10-30 VDC
  • Input current 100 mA @ 24 VDC (typical)
  • Operating Temp: -40 to +70°C  (-40 TO 85C storage)
  • Shock: IEC60068-2-27,
  • Vibration: IEC60068-2-6
  • Humidity: 5 to 95% non-condensing

 CERTIFICATIONS

  • Flammability UL 94V-0 materials
  • EMC: emissions FCC, part 15 and Industry Canada, ICES-003 Class A; EN55022; EN61326-1
  • EMC immunity EN61326-1 (EN61000-4-2,3,4,6)
  • Hazardous Locations: Class I, Div. 2, Groups A,B,C,D, UL1604, CSA C22.2/213, Cenelec EN50021 Zone 2
  • Electrical Safety: UL508/CSA22.2/14 (CUL); EN610101; (IEC1010)

 

 

 

Parabolic Trough Single Axis Controller

 

trough0ESAT (Enhanced Single Axis Tracking) is a unique calculation which finds the optimum angle of incidence at the lower solar elevations using the NREL equation. This improves efficiency in the winter months and is standard on all Tracker IPms.

With TLC (Temperature Limiting Control) and a Temperature Sensor, the Tracker IPm utilizes a Industrial Process Control PID loop to prevent over heating the temperature transfer medium by deflecting the tracker position. Efficiency is not lost since the loop can be tuned to maintain a set point of +/- 1 deg C.

Model Number: VT-IPM2M-133-SPA

Versions:

v404-1030-000   Standard Single Axis Control with ESAT

v404-1030-010   Standard Single Axis Control with ESAT & TLC

PERFORMANCE SPECIFICATIONS

  • Industrial powerPC (32 bit data bus)
  • Operating system embedded Linux
  • Dynamic memory (RAM) 32 Mbytes – 32bit, 0 wait states
  • Program memory (Flash) 32 Mbytes
  • Retained memory (RAM) 512K (battery-backed)
  • Data logging (OPTIONAL)
  • Custom programming available

ETHERNET PORT

  • 10/100BaseTx (auto-detecting)
  • RJ45 connection (auto-crossover)
  • Protocols TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP, DNP3 Slave

SERIAL PORT

  • RS485 port A screws (485+, 485-, GND) (2-wire half-duplex)
  • RS232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR,DSR, GND)
  • Protocols (master & slave) SIXNET & Modbus RTU/ASCII;
  • Flow control hardware, software, RTS-party (for radios and RS485)

DISCRETE INPUTS

  • 12 channels (sinking or sourcing)
  • Guaranteed ON voltage 9 VDC
  • Maximum voltage 30 VDC
  • Guaranteed OFF voltage & current 5.0 VDC & 1.5 mA DC
  • Input resistance 10K Ohms
  • Input current @ 24 VDC 3 mA
  • Filtered ON/OFF delay 25 mS (20 Hz max. counting)
  • Fast ON/OFF delay 4 mS (100 Hz max. counting)
  • Count rate (channels 1 – 8) (10 KHz on channel 1)

DISCRETE OUTPUTS

  • 4 channels (10-30 VDC)
  • Maximum output per channel 1 Amp
  • Maximum output per module 4 Amps
  • Max. OFF state leakage 0.05 mA
  • Minimum load 1 mA
  • Inrush current 5 Amps (100 mS surge)
  • Typical ON resistance 0.3 Ohms
  • Typical ON voltage (@1A) 0.3 VDC

ANALOG INPUTS

  • 8 channels (4-20 mA, 0-2VDC, 0-5VDC, 0-10VDC)
  • A/D resolution 16 bits (0.003%)
  • Full scale accuracy +/-0.1% (@20°C)
  • Span and offset temp. coef. +/-50 ppm per °C
  • Input impedance 100 Ohm
  • Current protection Self-resetting fuses
  • DMRR (differential mode rejection) 66 dB at 50/60 Hz

ANALOG OUTPUTS

  • up to 2 channels (4-20 mA, 0-20mA 0-10VDC with Resistor)
  • D/A resolution 16 bits (less than 1?A)
  • Full scale accuracy (@20°C) +/- 0.02%
  • Span and offset temp. coef. +/- 50 ppm per °C typical
  • Max. output settling time 5 mS (to .05%)
  • Load resistance range (@ +24 VDC supply) 0-750 Ohms
  • Short circuit protection current limiting

ENVIRONMENTAL

  • DIN rail or fl at panel mount
  • Input power 10-30 VDC
  • Input current 100 mA @ 24 VDC (typical)
  • Operating Temp: -40 to +70°C (-40 TO 85C storage)
  • Shock: IEC60068-2-27,
  • Vibration: IEC60068-2-6
  • Humidity: 5 to 95% non-condensing

CERTIFICATIONS

  • Flammability UL 94V-0 materials
  • EMC: emissions FCC, part 15 and Industry Canada, ICES-003 Class A; EN55022; EN61326-1
  • EMC immunity EN61326-1 (EN61000-4-2,3,4,6)
  • Hazardous Locations: Class I, Div. 2, Groups A,B,C,D, UL1604, CSA C22.2/213, Cenelec EN50021 Zone 2
  • Electrical Safety: UL508/CSA22.2/14 (CUL); EN610101; (IEC1010)